The FISHER-WALLACE CRANIAL STIMULATOR (model SBL500-B) may produce better results than the CES Ultra, AlphaStim and other less expensive devices because of its complex waveform and frequencies. The Model SBL500-B device is an electronic signal generator which is
indicated for the symptomatic relief of anxiety, depression, and insomnia. The Cranial Stimulator—allowed by the FDA to be marketed for symptom reduction in depression, anxiety, and insomnia—is a portable, battery-powered micro-current pulse generator. It is small enough to hold in one hand, and produces three biologically synchronous waveforms: 15,000 Hz, 15 Hz, and 500 Hz. The two slender electrical cables transmit current through either a small sponge that is moistened before use, or a self-adhesive patch. They are secured in place on the temples with a soft headband. Current flows between the two electrodes when the Fisher-Wallace Cranial Stimulator is turned on. The number of flashing lights on the Stimulator clearly indicates the level of stimulation, which is easily adjusted by the user. The current automatically turns off after 20 minutes. Clear instructions accompany the Fisher-Wallace Cranial Stimulator. Device SpecificationPARAMETER NOMINAL
VALUE +/-10% Waveform: Asymmetrical bipolar square wave with double modulation. This waveform contains 25 bursts of 15 pulses each. Each pulse is 33.3 microsecond duration in a pulse period of 66.7 microseconds. Power Source: 9 volt Alkaline Battery Limited WarrantyFisher-Wallace Laboratories, LLC warrants each new Fisher-Wallace Cranial Stimulator (Zero DC) (exclusive of batteries) to be free from defects in materials and workmanship for a period of 18 months and accessories (not including disposables) for a period of 90 days following the delivery of the Fisher-Wallace Cranial Stimulator to the original purchaser. The obligation of Fisher-Wallace Laboratories, LLC under this warranty is expressly limited solely and exclusively to the repair or replacement of the unit or any parts thereof, which to Fisher-Wallace Laboratories, LLC satisfaction, shall have become defective during the warranty period, and which shall have been returned to Fisher-Wallace Laboratories, LLC within 30 days after the discovery of the defect by the original purchaser. This warranty does not extend to any liability for medical or dental expenses, or for any other direct, indirect or consequential damages caused by the failure, defect or malfunction of the Fisher-Wallace Cranial Stimulator, except as herein provided, whether such damage claim shall be based on contract, tort, breach of warranty, or otherwise.
Liss device (pat # 4,627,438) From pat #6904322 Transcranial electrostimulation apparatus and method Transcranial electrostimulation (CES or TCES) originally was used in the
1960's to induce sleep; These early devices typically used less than 1.5
mA at 100 Hz. The Liss U.S. Pat. No. 4,627,438 employed higher frequencies
modulated by a lower frequency square
wave to produce recurring pulse bursts. The repetition frequency of
the device of Liss is determined by the modulation frequency; but the
pulse bursts are of a uniform amplitude within each repetition cycle. The
device of the Liss patent is specifically
directed to utilization in conjunction with the treatment of migraine
headaches. The low frequency or modulating signal is asymmetrical,
utilizing a 3:1 duty cycle, "on" three-fourths of the time and "off" one
fourth of the recurring period. This results in
bursts of the high frequency signal separated by the off time when no
signal is applied, following the re-application of the bursts of the high